Medical gas copper pipework is a fixed part of many healthcare gas distribution systems. Procurement teams should describe the pipe by the specified medical-gas tube requirements rather than by a general plumbing copper tube description.
What does EN 13348 cover?
EN 13348 addresses seamless, round copper tubes for medical gases or vacuum applications. It covers matters including material and dimensional requirements, testing and conditions of delivery. The 2016 edition replaced an earlier 2008 version in European adoption.
A relevant standard reference identifies a tube family; the actual order must still state the sizes, delivery form and quantities required by the project.
Straight lengths versus coils
Straight lengths are often selected for defined distribution runs. Coils may be used where the installation design calls for them. Select the form according to the piping design, site handling requirements and tube specification rather than treating the two forms as identical.
Explore BWC Medgas degreased copper tube in straight lengths and degreased copper tube coils.
Essential purchase dimensions
- Outside diameter of the tube
- Wall thickness
- Straight-length or coil form
- Temper or specified mechanical condition
- Quantity or total linear length
- Cleaning and end-protection requirements
- Required batch identification and documentation
- Applicable project specification and destination
The project drawing should define pipe dimensions; a product page alone cannot replace the system design schedule.
Matching copper fittings
The fitting list normally includes items such as elbows, tees, couplings and other connection parts. The fitting dimensions and intended joining method should align with the pipeline schedule.
BWC Medgas also lists degreased medical copper fittings, 90-degree elbows and equal tees.
How to avoid procurement mismatches
Provide a line-by-line schedule rather than a single instruction to quote 'medical copper pipe'. Separate tube sizes, fitting types and quantities. Include the project location, planned delivery form and any packaging instructions.
For projects using multiple outside diameters, identify corresponding fittings for each size. This prevents one quotation line from unintentionally covering only a subset of the required components.
Frequently asked questions
Can ordinary plumbing copper tube automatically be used for an MGPS?
The project specification should identify material and cleanliness requirements for medical gas applications. A generic description of plumbing tube does not establish those requirements.
Are medical copper coils and straight lengths priced in the same way?
Pricing units and packing can differ. Ask for consistent units and clearly separated delivery forms when comparing offers.
What is the simplest enquiry format?
List each diameter and wall thickness as a separate line, followed by length or coil requirements, quantity, fitting schedule and delivery address.
Browse products
See medical copper tubes, copper fittings and the medical copper tube enquiry checklist.




